APC Netbotz

APC Netbotz

Plugin: go.d.plugin Module: snmp

Maintained by Netdata

Overview​

Monitor APC Netbotz (sensor) with Netdata over SNMP. Netdata recognizes the device automatically by its sysObjectID (recognized across 1 device identifiers) and collects the metrics this profile declares — on top of the generic SNMP baseline — with no manual OID configuration.

Netdata's SNMP collector matches the device to the apc-netbotz.yaml profile via sysObjectID/sysDescr, then polls the OIDs it declares.

This integration is supported on all platforms.

This integration supports multiple instances configured side-by-side.

Default Behavior​

Auto-Detection​

Auto-detected as APC Netbotz via sysObjectID/sysDescr.

Limits​

The default configuration for this integration does not impose any limits.

Performance Impact​

The default configuration for this integration is not expected to impose a significant performance impact on the system.

Setup​

You can configure the snmp collector in two ways:

MethodBest forHow to
UIFast setup without editing filesGo to Nodes → Configure this node → Collectors → Jobs, search for snmp, then click + to add a job.
FileIf you prefer configuring via file, or need to automate deployments (e.g., with Ansible)Edit go.d/snmp.conf and add a job.
important

UI configuration requires paid Netdata Cloud plan.

Prerequisites​

SNMP access​

SNMP must be enabled on the device and reachable from the Netdata Agent acting as the site's SNMP hub.

Configuration​

Options​

Configure the SNMP collector with the device hostname and SNMP credentials. See the SNMP collector reference for all options.

via UI​

Configure the snmp collector from the Netdata web interface:

  1. Go to Nodes.
  2. Select the node where you want the snmp data-collection job to run and click the ⚙ (Configure this node). That node will run the data collection.
  3. The Collectors → Jobs view opens by default.
  4. In the Search box, type snmp (or scroll the list) to locate the snmp collector.
  5. Click the + next to the snmp collector to add a new job.
  6. Fill in the job fields, then click Test to verify the configuration and Submit to save.
    • Test runs the job with the provided settings and shows whether data can be collected.
    • If it fails, an error message appears with details (for example, connection refused, timeout, or command execution errors), so you can adjust and retest.

via File​

The configuration file name for this integration is go.d/snmp.conf.

The file format is YAML. Generally, the structure is:

update_every: 1
autodetection_retry: 0
jobs:
- name: some_name1
- name: some_name2

You can edit the configuration file using the edit-config script from the Netdata config directory.

cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/snmp.conf
Examples​

There are no configuration examples.

Alerts​

There are no alerts configured by default for this integration.

Metrics​

On top of the generic SNMP baseline (the Generic SNMP Device integration — interfaces, system, IP/TCP/UDP, host resources), this APC Netbotz profile adds the metrics below. Each is collected only where the device exposes the matching OID — inclusion means the profile requests it; availability depends on the device model and software.

18 metrics in 5 groups; each row is a chart context usable in alerts.

GroupMetrics
Hardware / Enclosure2
Hardware / Port2
Hardware / Sensor11
System / Alert2
System / Uptime1

Hardware / Enclosure​

Metric (chart context)UnitScopeDescription
snmp.device_prof_enclosureErrorStatus{status}per netbotz_enclosure_index, netbotz_enclosure_id, netbotz_enclosure_labelThe error status of the enclosure
snmp.device_prof_enclosureStatus{status}per netbotz_enclosure_index, netbotz_enclosure_id, netbotz_enclosure_labelThe status of the enclosure

Hardware / Port​

Metric (chart context)UnitScopeDescription
snmp.device_prof_dinPortStatus{status}per netbotz_din_port_index, netbotz_din_port_idThe error status of the sensor
snmp.device_prof_otherPortStatus{status}per netbotz_other_port_index, netbotz_other_port_id, netbotz_other_port_label, netbotz_other_port_enc_idThe error status of the sensor

Hardware / Sensor​

Metric (chart context)UnitScopeDescription
snmp.device_prof_dewPointSensorErrorStatus{status}per netbotz_dew_point_sensor_index, netbotz_dew_point_sensor_id, netbotz_dew_point_sensor_label, netbotz_dew_point_sensor_enc_idThe error status of the sensor
snmp.device_prof_dewPointSensorValueIntCelper netbotz_dew_point_sensor_index, netbotz_dew_point_sensor_id, netbotz_dew_point_sensor_label, netbotz_dew_point_sensor_enc_idThe dew point measured by the sensor
snmp.device_prof_dewPointSensorValueIntFdegFper netbotz_dew_point_sensor_index, netbotz_dew_point_sensor_id, netbotz_dew_point_sensor_label, netbotz_dew_point_sensor_enc_idThe dew point measured by the sensor
snmp.device_prof_doorSwitchSensorErrorStatus{status}per netbotz_door_switch_sensor_index, netbotz_door_switch_sensor_id, netbotz_door_switch_sensor_label, netbotz_door_switch_sensor_enc_id, netbotz_door_switch_sensor_value_strThe error status of the sensor
snmp.device_prof_doorSwitchSensorValue{status}per netbotz_door_switch_sensor_index, netbotz_door_switch_sensor_id, netbotz_door_switch_sensor_label, netbotz_door_switch_sensor_enc_id, netbotz_door_switch_sensor_value_strWhether the door is open or closed
snmp.device_prof_humiSensorErrorStatus{status}per netbotz_humi_sensor_index, netbotz_humi_sensor_id, netbotz_humi_sensor_label, netbotz_humi_sensor_enc_idThe error status of the sensor
snmp.device_prof_humiSensorValueInt%per netbotz_humi_sensor_index, netbotz_humi_sensor_id, netbotz_humi_sensor_label, netbotz_humi_sensor_enc_idThe relative humidity measured by the sensor
snmp.device_prof_otherStateSensorErrorStatus{status}per netbotz_other_state_sensor_label, netbotz_other_state_sensor_enc_id, netbotz_other_state_sensor_value_str, netbotz_other_state_sensor_idThe error status of the sensor
snmp.device_prof_tempSensorErrorStatus{status}per netbotz_temp_sensor_index, netbotz_temp_sensor_id, netbotz_temp_sensor_label, netbotz_temp_sensor_enc_idThe error status of the sensor
snmp.device_prof_tempSensorValueIntCelper netbotz_temp_sensor_index, netbotz_temp_sensor_id, netbotz_temp_sensor_label, netbotz_temp_sensor_enc_idThe temperature measured by the sensor
snmp.device_prof_tempSensorValueIntFdegFper netbotz_temp_sensor_index, netbotz_temp_sensor_id, netbotz_temp_sensor_label, netbotz_temp_sensor_enc_idThe temperature measured by the sensor

System / Alert​

Metric (chart context)UnitScopeDescription
snmp.device_prof_errorCondResolved{status}per netbotz_error_cond_index, netbotz_error_cond_id, netbotz_error_cond_type_id, netbotz_error_cond_enc_id, netbotz_error_cond_sensor_idWhether the error condition was resolved
snmp.device_prof_errorCondSeverity{status}per netbotz_error_cond_index, netbotz_error_cond_id, netbotz_error_cond_type_id, netbotz_error_cond_enc_id, netbotz_error_cond_sensor_idThe relative severity of the error condition

System / Uptime​

Metric (chart context)UnitScopeDescription
snmp.device_prof_systemUptimesdeviceTime since the system was last rebooted or powered on.

Troubleshooting​

Other Problems​

Collect Diagnostics for Netdata Support​

For SNMP metrics, BGP, licensing, or topology issues, follow Collect SNMP troubleshooting data to include built-in diagnostics in a support bundle. SNMP evidence is unsanitized; share the bundle through a restricted Netdata Support ticket.


Do you have any feedback for this page? If so, you can open a new issue on our netdata/learn repository.