Skip to main content

HPE Bladesystem Enclosure

HPE Bladesystem Enclosure

Plugin: go.d.plugin Module: snmp

Maintained by Netdata

Overview​

Monitor HPE Bladesystem Enclosure (network device) with Netdata over SNMP. Netdata recognizes the device automatically by its sysObjectID (recognized across 1 device identifiers) and collects the metrics this profile declares — on top of the generic SNMP baseline — with no manual OID configuration.

Netdata's SNMP collector matches the device to the hpe-bladesystem-enclosure.yaml profile via sysObjectID/sysDescr, then polls the OIDs it declares.

This integration is supported on all platforms.

This integration supports multiple instances configured side-by-side.

Default Behavior​

Auto-Detection​

Auto-detected as HPE Bladesystem Enclosure via sysObjectID/sysDescr.

Limits​

The default configuration for this integration does not impose any limits.

Performance Impact​

The default configuration for this integration is not expected to impose a significant performance impact on the system.

Setup​

You can configure the snmp collector in two ways:

MethodBest forHow to
UIFast setup without editing filesGo to Nodes → Configure this node → Collectors → Jobs, search for snmp, then click + to add a job.
FileIf you prefer configuring via file, or need to automate deployments (e.g., with Ansible)Edit go.d/snmp.conf and add a job.
important

UI configuration requires paid Netdata Cloud plan.

Prerequisites​

SNMP access​

SNMP must be enabled on the device and reachable from the Netdata Agent acting as the site's SNMP hub.

Configuration​

Options​

Configure the SNMP collector with the device hostname and SNMP credentials. See the SNMP collector reference for all options.

via UI​

Configure the snmp collector from the Netdata web interface:

  1. Go to Nodes.
  2. Select the node where you want the snmp data-collection job to run and click the ⚙ (Configure this node). That node will run the data collection.
  3. The Collectors → Jobs view opens by default.
  4. In the Search box, type snmp (or scroll the list) to locate the snmp collector.
  5. Click the + next to the snmp collector to add a new job.
  6. Fill in the job fields, then click Test to verify the configuration and Submit to save.
    • Test runs the job with the provided settings and shows whether data can be collected.
    • If it fails, an error message appears with details (for example, connection refused, timeout, or command execution errors), so you can adjust and retest.

via File​

The configuration file name for this integration is go.d/snmp.conf.

The file format is YAML. Generally, the structure is:

update_every: 1
autodetection_retry: 0
jobs:
- name: some_name1
- name: some_name2

You can edit the configuration file using the edit-config script from the Netdata config directory.

cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/snmp.conf
Examples​

There are no configuration examples.

Alerts​

There are no alerts configured by default for this integration.

Metrics​

On top of the generic SNMP baseline (the Generic SNMP Device integration — interfaces, system, IP/TCP/UDP, host resources), this HPE Bladesystem Enclosure profile adds the metrics below. Each is collected only where the device exposes the matching OID — inclusion means the profile requests it; availability depends on the device model and software.

65 metrics in 12 groups; each row is a chart context usable in alerts.

GroupMetrics
Hardware / EnclosureManager4
Hardware / Fan3
Hardware / Fuse2
Hardware / Power7
Hardware / PowerEnclosure4
Hardware / Sensor2
Hardware / ServerBlade10
Network / Interface4
System / CPU2
System / Disk15
System / Memory11
System / Uptime1

Hardware / EnclosureManager​

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpqRackCommonEnclosureManagerCondition{status}per cpq_rack_common_enclosure_manager_enclosure_rack, cpq_rack_common_enclosure_manager_enclosure_chassis, cpq_rack_common_enclosure_manager_enclosure_indexThe condition of the manager
snmp.device_prof_cpqRackCommonEnclosureManagerPresent{status}per cpq_rack_common_enclosure_manager_enclosure_rack, cpq_rack_common_enclosure_manager_enclosure_chassis, cpq_rack_common_enclosure_manager_enclosure_indexThis specifies if the manager described is present in the system
snmp.device_prof_cpqRackCommonEnclosureManagerRedundant{status}per cpq_rack_common_enclosure_manager_enclosure_rack, cpq_rack_common_enclosure_manager_enclosure_chassis, cpq_rack_common_enclosure_manager_enclosure_indexThis specifies if the manager is in a redundant configuration
snmp.device_prof_cpqRackCommonEnclosureManagerRole{status}per cpq_rack_common_enclosure_manager_enclosure_rack, cpq_rack_common_enclosure_manager_enclosure_chassis, cpq_rack_common_enclosure_manager_enclosure_indexThis specifies the current role of the manager

Hardware / Fan​

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpqRackCommonEnclosureFanCondition{status}per cpq_rack_common_enclosure_fan_rack, cpq_rack_common_enclosure_fan_chassis, cpq_rack_common_enclosure_fan_indexThe condition of the fan
snmp.device_prof_cpqRackCommonEnclosureFanPresent{status}per cpq_rack_common_enclosure_fan_rack, cpq_rack_common_enclosure_fan_chassis, cpq_rack_common_enclosure_fan_indexThis specifies if the fan described is present in the system
snmp.device_prof_cpqRackCommonEnclosureFanRedundant{status}per cpq_rack_common_enclosure_fan_rack, cpq_rack_common_enclosure_fan_chassis, cpq_rack_common_enclosure_fan_indexThis specifies if the fan is in a redundant configuration

Hardware / Fuse​

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpqRackCommonEnclosureFuseCondition{status}per cpq_rack_common_enclosure_fuse_rack, cpq_rack_common_enclosure_fuse_chassis, cpq_rack_common_enclosure_fuse_index, cpq_rack_common_enclosure_fuse_enclosure_name, cpq_rack_common_enclosure_fuse_locationThe condition of the fuse
snmp.device_prof_cpqRackCommonEnclosureFusePresent{status}per cpq_rack_common_enclosure_fuse_rack, cpq_rack_common_enclosure_fuse_chassis, cpq_rack_common_enclosure_fuse_index, cpq_rack_common_enclosure_fuse_enclosure_name, cpq_rack_common_enclosure_fuse_locationThis specifies if the fuse described is present in the system

Hardware / Power​

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpqRackPowerSupplyCondition{status}per cpq_rack_power_supply_enclosure_rack, cpq_rack_power_supply_enclosure_chassis, cpq_rack_power_supply_enclosure_indexThe condition of the power supply
snmp.device_prof_cpqRackPowerSupplyCurPwrOutputWper cpq_rack_power_supply_enclosure_rack, cpq_rack_power_supply_enclosure_chassis, cpq_rack_power_supply_enclosure_indexThe current power output of the power supply in watts
snmp.device_prof_cpqRackPowerSupplyExhaustTempCelper cpq_rack_power_supply_enclosure_rack, cpq_rack_power_supply_enclosure_chassis, cpq_rack_power_supply_enclosure_indexThe current air temperature at the exhaust of the power supply in degrees celsius
snmp.device_prof_cpqRackPowerSupplyInputLineStatus{status}per cpq_rack_power_supply_enclosure_rack, cpq_rack_power_supply_enclosure_chassis, cpq_rack_power_supply_enclosure_indexThe status of line input power
snmp.device_prof_cpqRackPowerSupplyIntakeTempCelper cpq_rack_power_supply_enclosure_rack, cpq_rack_power_supply_enclosure_chassis, cpq_rack_power_supply_enclosure_indexThe current air temperature at the intake of the power supply in degrees celsius
snmp.device_prof_cpqRackPowerSupplyPresent{status}per cpq_rack_power_supply_enclosure_rack, cpq_rack_power_supply_enclosure_chassis, cpq_rack_power_supply_enclosure_indexThis specifies if the power supply described is present in the enclosure
snmp.device_prof_cpqRackPowerSupplyStatus{status}per cpq_rack_power_supply_enclosure_rack, cpq_rack_power_supply_enclosure_chassis, cpq_rack_power_supply_enclosure_indexThe status of the power supply

Hardware / PowerEnclosure​

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpqRackPowerEnclosureBladeAutopoweron{status}per cpq_rack_power_enclosure_rack, cpq_rack_power_enclosure_index, cpq_rack_power_enclosure_input_pwr_typeThis indicates current condition of the power enclosure
snmp.device_prof_cpqRackPowerEnclosureCondition{status}per cpq_rack_power_enclosure_rack, cpq_rack_power_enclosure_index, cpq_rack_power_enclosure_input_pwr_typeThis indicates current condition of the power enclosure
snmp.device_prof_cpqRackPowerEnclosureLoadBalanced{status}per cpq_rack_power_enclosure_rack, cpq_rack_power_enclosure_index, cpq_rack_power_enclosure_input_pwr_typeThis indicates if the power supply enclosure is in a load balanced state
snmp.device_prof_cpqRackPowerEnclosureRedundant{status}per cpq_rack_power_enclosure_rack, cpq_rack_power_enclosure_index, cpq_rack_power_enclosure_input_pwr_typeThis indicates if the power supply enclosure is in a redundant state

Hardware / Sensor​

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpqRackCommonEnclosureTempCondition{status}per cpq_rack_common_enclosure_temp_rack, cpq_rack_common_enclosure_temp_chassis, cpq_rack_common_enclosure_temp_sensor_index, cpq_rack_common_enclosure_temp_sensor_enclosure_name, cpq_rack_common_enclosure_temp_location, cpq_rack_common_enclosure_temp_typeThe Temperature sensor condition
snmp.device_prof_cpqRackCommonEnclosureTempCurrentCelper cpq_rack_common_enclosure_temp_rack, cpq_rack_common_enclosure_temp_chassis, cpq_rack_common_enclosure_temp_sensor_index, cpq_rack_common_enclosure_temp_sensor_enclosure_name, cpq_rack_common_enclosure_temp_location, cpq_rack_common_enclosure_temp_typeThis is the current temperature sensor reading in degrees celsius

Hardware / ServerBlade​

Metric (chart context)UnitScopeDescription
snmp.device_prof_cpqRackServerBladeFaultMajor{fault_code}per cpq_rack_server_blade_rack, cpq_rack_server_blade_chassis, cpq_rack_server_blade_indexThe major fault code of the blade fault reported by the enclosure manager
snmp.device_prof_cpqRackServerBladeFaultMinor{fault_code}per cpq_rack_server_blade_rack, cpq_rack_server_blade_chassis, cpq_rack_server_blade_indexThe minor fault code of the blade fault reported by the enclosure manager
snmp.device_prof_cpqRackServerBladeHasFuses{status}per cpq_rack_server_blade_rack, cpq_rack_server_blade_chassis, cpq_rack_server_blade_indexThis specifies if the server blade contains fuses
snmp.device_prof_cpqRackServerBladePOSTStatus{status}per cpq_rack_server_blade_rack, cpq_rack_server_blade_chassis, cpq_rack_server_blade_indexBlade server power-on self test (POST) status
snmp.device_prof_cpqRackServerBladePowered{status}per cpq_rack_server_blade_rack, cpq_rack_server_blade_chassis, cpq_rack_server_blade_indexThe power state of the blade
snmp.device_prof_cpqRackServerBladePresent{status}per cpq_rack_server_blade_rack, cpq_rack_server_blade_chassis, cpq_rack_server_blade_indexThis specifies if the server blade described is present in the enclosure
snmp.device_prof_cpqRackServerBladeStatus{status}per cpq_rack_server_blade_rack, cpq_rack_server_blade_chassis, cpq_rack_server_blade_indexThe health status of the blade
snmp.device_prof_cpqRackServerBladeUIDState{status}per cpq_rack_server_blade_rack, cpq_rack_server_blade_chassis, cpq_rack_server_blade_indexThe Unit Identifier LED status
snmp.device_prof_cpqRackServerTempSensorCondition{status}per cpq_rack_server_temp_sensor_rack, cpq_rack_server_temp_sensor_chassis, cpq_rack_server_temp_sensor_index, cpq_rack_server_temp_sensor_typeThe Temperature sensor condition
snmp.device_prof_cpqRackServerTempSensorCurrentCelper cpq_rack_server_temp_sensor_rack, cpq_rack_server_temp_sensor_chassis, cpq_rack_server_temp_sensor_index, cpq_rack_server_temp_sensor_typeThis is the current temperature sensor reading in degrees celsius

Network / Interface​

Metric (chart context)UnitScopeDescription
snmp.device_prof_ifAdminStatus{status}per interface, interfaceCurrent administrative state of the interface
snmp.device_prof_ifHighSpeedbit/sper interface, interfaceEstimate of the interface's current bandwidth
snmp.device_prof_ifNumber{interface}deviceNumber of network interfaces regardless of their current state present on this system
snmp.device_prof_ifOperStatus{status}per interface, interfaceCurrent operational state of the interface

System / CPU​

Metric (chart context)UnitScopeDescription
snmp.device_prof_ucd_ssRawContexts{switch}/sdeviceNumber of context switches
snmp.device_prof_ucd_ssRawInterrupts{interrupt}/sdeviceNumber of interrupts processed

System / Disk​

Metric (chart context)UnitScopeDescription
snmp.device_prof_ucd_diskIOLA1%per ucd_disk_io_deviceThe 1 minute average load of disk (%)
snmp.device_prof_ucd_diskIOLA15%per ucd_disk_io_deviceThe 15 minute average load of disk (%)
snmp.device_prof_ucd_diskIOLA5%per ucd_disk_io_deviceThe 5 minute average load of disk (%)
snmp.device_prof_ucd_diskIONReadXBy/sper ucd_disk_io_deviceThe number of bytes read from this device since boot
snmp.device_prof_ucd_diskIONWrittenXBy/sper ucd_disk_io_deviceThe number of bytes written to this device since boot
snmp.device_prof_ucd_diskIOReads{read}/sper ucd_disk_io_deviceThe number of read accesses from this device since boot
snmp.device_prof_ucd_diskIOWrites{write}/sper ucd_disk_io_deviceThe number of write accesses to this device since boot
snmp.device_prof_ucd_dskAvailByper ucd_dsk_path, ucd_dsk_deviceAvailable space on the disk
snmp.device_prof_ucd_dskErrorFlag{status}per ucd_dsk_path, ucd_dsk_deviceFlag signaling that the disk or partition is under the minimum required space configured for it
snmp.device_prof_ucd_dskPercent%per ucd_dsk_path, ucd_dsk_devicePercentage of space used on disk
snmp.device_prof_ucd_dskPercentNode%per ucd_dsk_path, ucd_dsk_devicePercentage of inodes used on disk
snmp.device_prof_ucd_dskTotalByper ucd_dsk_path, ucd_dsk_deviceTotal size of the disk/partition
snmp.device_prof_ucd_dskUsedByper ucd_dsk_path, ucd_dsk_deviceUsed space on the disk
snmp.device_prof_ucd_ssIORawReceivedBy/sdeviceAmount of data read from disk or other block device
snmp.device_prof_ucd_ssIORawSentBy/sdeviceAmount of data written to disk or other block device

System / Memory​

Metric (chart context)UnitScopeDescription
snmp.device_prof_memory_freeBydeviceThe amount of real/physical memory currently unused or available
snmp.device_prof_ucd_memAvailSwapBydeviceThe amount of swap space currently unused or available
snmp.device_prof_ucd_memBufferBydeviceThe total amount of real or virtual memory currently allocated for use as memory buffers
snmp.device_prof_ucd_memCachedBydeviceThe total amount of real or virtual memory currently allocated for use as cached memory
snmp.device_prof_ucd_memMinimumSwapBydeviceThe minimum amount of swap space expected to be kept free or available during normal operation of this host
snmp.device_prof_ucd_memSharedBydeviceThe total amount of real or virtual memory currently allocated for use as shared memory
snmp.device_prof_ucd_memTotalFreeBydeviceThe total amount of memory free or available for use on this host
snmp.device_prof_ucd_memTotalSwapBydeviceThe total amount of swap space configured for this host
snmp.device_prof_ucd_memoryTotalBydeviceThe total amount of real/physical memory installed on this host
snmp.device_prof_ucd_ssRawSwapInBy/sdeviceAmount of memory swapped in from disk
snmp.device_prof_ucd_ssRawSwapOutBy/sdeviceAmount of memory swapped out to disk

System / Uptime​

Metric (chart context)UnitScopeDescription
snmp.device_prof_systemUptimesdeviceTime since the system was last rebooted or powered on.

Troubleshooting​

Other Problems​

Collect Diagnostics for Netdata Support​

For SNMP metrics, BGP, licensing, or topology issues, follow Collect SNMP troubleshooting data to include built-in diagnostics in a support bundle. SNMP evidence is unsanitized; share the bundle through a restricted Netdata Support ticket.


Do you have any feedback for this page? If so, you can open a new issue on our netdata/learn repository.