Servertech Pdu3

Servertech Pdu3

Plugin: go.d.plugin Module: snmp

Maintained by Netdata

Overview​

Monitor Servertech Pdu3 (pdu) with Netdata over SNMP. Netdata recognizes the device automatically by its sysObjectID (recognized across 1 device identifiers) and collects the metrics this profile declares — on top of the generic SNMP baseline — with no manual OID configuration.

Netdata's SNMP collector matches the device to the servertech-pdu3.yaml profile via sysObjectID/sysDescr, then polls the OIDs it declares.

This integration is supported on all platforms.

This integration supports multiple instances configured side-by-side.

Default Behavior​

Auto-Detection​

Auto-detected as Servertech Pdu3 via sysObjectID/sysDescr.

Limits​

The default configuration for this integration does not impose any limits.

Performance Impact​

The default configuration for this integration is not expected to impose a significant performance impact on the system.

Setup​

You can configure the snmp collector in two ways:

MethodBest forHow to
UIFast setup without editing filesGo to Nodes → Configure this node → Collectors → Jobs, search for snmp, then click + to add a job.
FileIf you prefer configuring via file, or need to automate deployments (e.g., with Ansible)Edit go.d/snmp.conf and add a job.
important

UI configuration requires paid Netdata Cloud plan.

Prerequisites​

SNMP access​

SNMP must be enabled on the device and reachable from the Netdata Agent acting as the site's SNMP hub.

Configuration​

Options​

Configure the SNMP collector with the device hostname and SNMP credentials. See the SNMP collector reference for all options.

via UI​

Configure the snmp collector from the Netdata web interface:

  1. Go to Nodes.
  2. Select the node where you want the snmp data-collection job to run and click the ⚙ (Configure this node). That node will run the data collection.
  3. The Collectors → Jobs view opens by default.
  4. In the Search box, type snmp (or scroll the list) to locate the snmp collector.
  5. Click the + next to the snmp collector to add a new job.
  6. Fill in the job fields, then click Test to verify the configuration and Submit to save.
    • Test runs the job with the provided settings and shows whether data can be collected.
    • If it fails, an error message appears with details (for example, connection refused, timeout, or command execution errors), so you can adjust and retest.

via File​

The configuration file name for this integration is go.d/snmp.conf.

The file format is YAML. Generally, the structure is:

update_every: 1
autodetection_retry: 0
jobs:
- name: some_name1
- name: some_name2

You can edit the configuration file using the edit-config script from the Netdata config directory.

cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/snmp.conf
Examples​

There are no configuration examples.

Alerts​

There are no alerts configured by default for this integration.

Metrics​

On top of the generic SNMP baseline (the Generic SNMP Device integration — interfaces, system, IP/TCP/UDP, host resources), this Servertech Pdu3 profile adds the metrics below. Each is collected only where the device exposes the matching OID — inclusion means the profile requests it; availability depends on the device model and software.

33 metrics in 9 groups; each row is a chart context usable in alerts.

GroupMetrics
Hardware / Infeed2
Hardware / Outlet3
Hardware / Sensor6
Hardware / Tower1
PowerFlow / Infeed10
PowerFlow / System1
PowerFlow / Tower8
System / Configuration1
System / Uptime1

Hardware / Infeed​

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_infeedLoadStatus{status}per servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed load status
snmp.device_prof_servertech_sentry3_infeedStatus{status}per servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed operational status

Hardware / Outlet​

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_outletControlState{status}per servertech_sentry3_outlet_id, servertech_sentry3_outlet_nameOutlet control state
snmp.device_prof_servertech_sentry3_outletStatus{status}per servertech_sentry3_outlet_id, servertech_sentry3_outlet_nameOutlet operational status
snmp.device_prof_servertech_sentry3_outletWakeupState{status}per servertech_sentry3_outlet_id, servertech_sentry3_outlet_nameOutlet wakeup state configuration

Hardware / Sensor​

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_envMonStatus{status}per servertech_sentry3_env_mon_id, servertech_sentry3_env_mon_nameEnvironmental monitor status
snmp.device_prof_servertech_sentry3_tempHumidSensorHumidStatus{status}per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameHumidity sensor status
snmp.device_prof_servertech_sentry3_tempHumidSensorHumidValue%per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameHumidity value from sensor
snmp.device_prof_servertech_sentry3_tempHumidSensorStatus{status}per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameTemperature/humidity sensor communication status
snmp.device_prof_servertech_sentry3_tempHumidSensorTempStatus{status}per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameTemperature sensor status
snmp.device_prof_servertech_sentry3_tempHumidSensorTempValueCelper servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_nameTemperature value from sensor

Hardware / Tower​

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_towerStatus{status}per servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower operational status

PowerFlow / Infeed​

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_infeedCapacityVAper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed capacity
snmp.device_prof_servertech_sentry3_infeedCapacityUsedVAper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameUsed infeed capacity
snmp.device_prof_servertech_sentry3_infeedEnergyWhper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed energy consumption
snmp.device_prof_servertech_sentry3_infeedLoadValueWper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed load value
snmp.device_prof_servertech_sentry3_infeedOutletCount{outlet}per servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameNumber of outlets on infeed
snmp.device_prof_servertech_sentry3_infeedPhaseCurrentAper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed phase current
snmp.device_prof_servertech_sentry3_infeedPhaseVoltageVper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed phase voltage
snmp.device_prof_servertech_sentry3_infeedPowerWper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed power
snmp.device_prof_servertech_sentry3_infeedReactance{status}per servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed reactance type
snmp.device_prof_servertech_sentry3_infeedVoltageVper servertech_sentry3_infeed_id, servertech_sentry3_infeed_nameInfeed voltage

PowerFlow / System​

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_systemTotalPowerWdeviceTotal power consumption of the system

PowerFlow / Tower​

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_towerActivePowerWper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower active power
snmp.device_prof_servertech_sentry3_towerApparentPowerVAper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower apparent power
snmp.device_prof_servertech_sentry3_towerEnergyWhper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower energy consumption
snmp.device_prof_servertech_sentry3_towerInfeedCount{infeed}per servertech_sentry3_tower_id, servertech_sentry3_tower_nameNumber of tower infeeds
snmp.device_prof_servertech_sentry3_towerLineFrequencyHzper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower line frequency
snmp.device_prof_servertech_sentry3_towerPowerFactor%per servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower power factor
snmp.device_prof_servertech_sentry3_towerVACapacityVAper servertech_sentry3_tower_id, servertech_sentry3_tower_nameTower VA capacity
snmp.device_prof_servertech_sentry3_towerVACapacityUsedVAper servertech_sentry3_tower_id, servertech_sentry3_tower_nameUsed tower VA capacity

System / Configuration​

Metric (chart context)UnitScopeDescription
snmp.device_prof_servertech_sentry3_systemConfigModifiedCount{modification}deviceCount of system configuration modifications

System / Uptime​

Metric (chart context)UnitScopeDescription
snmp.device_prof_systemUptimesdeviceTime since the system was last rebooted or powered on.